EasyManua.ls Logo

Stihl SR 450 - AV Springs at Bottom; Of Backplate; AV Springs on; Unit, SR

Stihl SR 450
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49SR 430, SR 450
7.2 AV Springs at Bottom of
Backplate
: Unscrew the anti-vibration
springs (arrows) from the bearing
plugs.
: Unscrew the bearing
plugs (arrows) from the anti-
vibration springs.
Screw the bearing plugs (1) into
the springs as far as stop.
0002RA134 TG0002RA135 TG
1
Installing
: Screw the preassembled
anti-vibration springs onto the
bearing plugs (arrow) as far as
stop.
Install the blower housing,
SR 430 b 10.7,
SR 450 b 10.8
Reassemble all other parts in the
reverse sequence.
7.3 AV Springs on Backplate,
Metering Unit, SR 450
Remove the metering unit,
b 10.3
: Unscrew the anti-vibration
springs from the bearing
plugs (arrows) .
0002RA136 TG0002RA433 TG
: Unscrew the bearing plugs (1)
from the anti-vibration springs.
Screw the bearing plugs (1) into
the springs as far as stop.
Installing
: Screw the preassembled
anti-vibration springs onto the
bearing plugs (arrow) as far as
stop.
Install the metering unit, b 10.3
Reassemble all other parts in the
reverse sequence.
0002RA135 TG
1
0002RA434 TG

Table of Contents