86 SR 430, SR 450
: Fit the gasket (1) into the
groove (arrow).
: On the underside, engage the
cutouts in the gasket over the
lugs (arrows).
Hold the rotary shutter with the
toothed pivot pin (1)
pointing in the direction of
the anti-vibration spring (2).
: Fit the rotary shutter (3) in
the hole (arrow).
0002RA337 TG
1
0002RA338 TG
0002RA339 TG
1
2
3
: Push the pivot pin (1) into the
hole (arrow).
: Fit the lever (1) into the hole so
that it engages the teeth.
Push the lever (1) fully home.
Check operation
the rotary shutter must open
and close when the lever is
turned.
: Insert and tighten down the
screw (1) firmly.
0002RA340 TG
1
0002RA341 TG
1
0002RA363 TG
1
Install the cable, b 10.4
Make sure that the
gasket (1) is properly
seated.
Position the metering unit (1) with
AV springs in the seats and push
it into place.
: Push the clamping strap (2) into
place.
: Insert the screws (arrows) and
tighten them down firmly.
0002RA138 TG
1
0002RA479 TG
1
2