To protect batteries against moisture, do
not store them directly on the floor
Due to the fire risk, store batteries outside
buildings
Store in a cool, dry and well-ventilated area
Never subject the battery to temperatures
below -35°C and above 80°C.
Long-term storage below -10°C or above 50°C
has a negative impact on the service life of the
battery.
After three months, check the charge state
of the battery and recharge if necessary
Cordon off the relevant area of the ware-
house
Only persons who are aware of the risks
and safety regulations may access this area
Protect against direct sunlight
Protect against precipitation
Store in a way that protects the batteries
against short circuits
Store batteries at a safe distance from flam-
mable materials
Do not store batteries together with metallic
objects
Store lithium-ion batteries separately from
other types of batteries (no mixed storage)
Maintain a safety margin of at least 2.5 m
from other goods
To avoid a deep discharge, observe the
specifications of the battery manufacturer
regarding the maximum permissible storage
period
If you have any questions, contact your au-
thorised service centre.
Checking the battery charge sta-
tus (lithium-ion battery)
The charge state of the lithium-ion battery can
be read on the display-operating unit of the
truck and on the display of the lithium-ion
Operating
4
Handling the lithium-ion battery (variant)
24950988078001 EN - 11/2021 - 10