EasyManua.ls Logo

STRATOS 25 - 7.2 Residual Hardness Regulation

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
7. Start-Up
20
Then measure the water hardness present on the outlet of
the system and check that it fits within the desired values.
Otherwise, adjust the regulator and check again.
WARNING: The hardness regulator is supplied in the closed
position, therefore, if the system is not adjusted, it will supply fully
softened water.
nutes in order to make sure that the remaining air has been
purged.
11. Cancel the current regeneration stage and move forward
to the filling stage of the tank. Now the brine tank will auto-
matically start to fill up with water. Let this stage run the full
process. At the end of the stage, the system will finish the
regeneration which was started in point 6.
12. Start another regeneration according to point 6 and wait
until the system reaches the Backwash stage. Press any button
to mover forward to the Brine suction stage.
13. The system should suck water from the brine tank. Let
the suction work for some minutes just to make sure that it is
working properly.
14. Cancel all the remaining stages of the regeneration.
15. Put the by-pass in the service mode and check that trea-
ted water is properly softened (see ‘Section 7.3’).
16. Charge the brine tank with salt.
17. The system is ready to operate.
’DANGER’ There is a danger of injury due to an excess of weight.
It is necessary that at least two persons move and rise the salt
bags. There is a danger of suffering back injuries and other body injuries.
7.2 Residual Hardness Regulation
As mentioned in ‘Section 2.7’, it is not recommended to su-
pply completely softened water to household supplies.
In order to modify the residual hardness, lightly open the regu-
lating valve, as indicated in the image below.