1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
t>155C
PROTECTION
M1
MUST BE SHORT CIRCUIT
PROTECTED WITH EXTERNAL
FUSES ACCORDING TO LOCAL
REGULATIONS
F = 16Amp MAXIMUM
W1
M1
15183100
COLOR CODES:
WH = WHITE
BN = BROWN
GN = GREEN
YE = YELLOW
GY = GREY
RD = RED
PLATE
BOTTOM
PLATE
BOTTOM
FRAME PLATE
PLATE
YE/GN YE/GN
BL = BLUE
YE/GN
YE/GN
THERMAL
QS1
POWER ON
F1
F2
REAR
W2
3x1mm2
REAR
A2
A1
246
BK1
BK2
4
START
STOP
SELECT
TO
W3
BK = BLACK
POWER
THERMAL
PROTECTION
M2
REAR
2x6,3AMP
ALL WIRINGS 1², EXCEPT OTHERW ISE MARKED.
135
3
1
2
11a
2b
2
PLATE
PLATE
REARFRONT
X3
X2
X1
BK3
BK4
W4
5x1mm²
BK5
BK2
3x1mm²
LABO POL-1
M
2 ~
MAINS SUPPLY:
100V/50Hz.
100V/60Hz.
220-240V/50Hz.
220-240V/60Hz.
110-120V/60Hz.
50µF
40µF
30µF
10µF
8µF
DEM/DEM
3x0,75mm²
BK9
BK11
BK10
C1
*
*
LaboForce-x
LaboForce-x
FROM
LaboForce
SELECT
LaboForce
T1
T2
W4
W4
BK1
BK2
BK4
BK5
W4YE/GN
L
N
PE
4
2
PE
1
3
2
A
Rev. A (04-09-97 FTH):
F1, F2 changed from 5,0A to 6,3A
Friday, September 29, 1995
CIRCUIT DIAGRAM
STRUERS A/S
VALHOEJSALLE 176
DK-2610 ROEDOVRE
DENMARK
PHONE:+45 3670 3500
11
A2
Size CAGE CODE DWG NO Rev
SCALE Sheet of
K1
U1
U5
U6
K1
S3
XPE2
XPE3
XPE1
S3
XPE2
XPE3
XPE5
XPE6 XPE4
S2
S1
C1
L2
L1
PE
L2
L1
PE
PE
FT2
FT2