- 11 –
Cont ...
5 TECHNICAL SPECIFICATION
Pump Model
PH 35 TS
50 Hz
46496
PH 35 TS
50 Hz
46445
PH 45 TS
50 Hz
46504
PH 45 TS
50 Hz
46448
General
Guarantee 2 years
WRAS approval Approved materials
Approvals CE
Features
Pump type Peripheral
Priming vent plug
ü ü ü ü
Typical noise 56 dB(A)
Materials
Pump body Brass
Impeller Brass
Mechanical seal
EPDM / PTFE /
Al. Oxide
Viton / Carbon
/ Silicon
Carbide
EPDM / PTFE /
Al. Oxide
Viton / Carbon
/ Silicon
Carbide
Performance
Maximum head – closed valve 3.0 bar / 30 metres 4.2 bar / 42 metres
Performance @ 9 l/min 2.3 bar / 23 metres 3.3 bar / 33 metres
Performance @ 18 l/min 1.4 bar / 14 metres 2.4 bar / 24 metres
Maximum flow 34 l/min 44 l/min
Minimum static inlet pressure 0.05 bar (0.5 metres)
Maximum static inlet pressure 1.4 bar (14 metres)
Maximum working pressure* 600 kPa (6 bar)
Maximum viscosity 50 secs redwood no. 1 9.5 centistokes
Maximum ambient air temperature 40
o
C
Min / Max water temperature Min 4
o
C / Max 80
o
C
Maximum suction lift** 4.6 metres
Connections Pump connections G ¾ female
Motor
Type Induction, auto-reset thermal trip
Duty rating Continuous (S1) @ 2.5 l/min and above
Electrical
Power supply (Vac/Ph/Hz) 230 V a.c. / 1 / 50 Hz
Power consumption – P1 410 Watts 600 Watts
Current – full load 1.8 Amps 2.6 Amps
Fuse rating 5 Amps
Power cable length 1.5 metres (pre-wired)
Physical
Enclosure protection IP44
Length 209 mm 225 mm
Width 132 mm
Height – excluding hoses 169 mm
Weight – including fittings 4.4 Kg 6.0 Kg

Related product manuals