FFFFF
ALARMS
The following chart shows the meaning of the alarm codes.
Alarm temperature blast chilling or temperature deep freezing not over within the maximum
time
Solutions:
- check the value of parameters r5 and r6 and AA.
Main consequences:
- the device will save the alarm.
Minimum temperature alarm.
Solutions:
- check the cell temperature
- check the value of parameters A1 and A2.
Main consequences:
- the device keeps working normally.
Maximum temperature alarm (alarm HACCP).
Solutions:
- check the cell temperature
- check the value of parameters A4 and A5.
Main consequences:
- the device will save the alarm.
Open door alarm.
Solutions:
- check the door state
- check the value of parameters i0 and i1.
Main consequences:
- effect set by the parameter i0.
high pressure alarm.
Solutions:
- check the state of the high pressure input
- check the value of parameters i5 and i6.
Main consequences:
- effect set by the parameter i5.
Power breakdown alarm
Solutions:
- check the connection decive-power
- check the value of parameters A10.
Main consequences:
- the device will save the alarm.