Tips for Safe Operation
The 3 core AC mains cable should be terminated with this
AC mains plug by connecting brown/red wire on live pin
(L), black/blue wire on neutral pin (N) and yellow/green
wire on earth pin (E).
The amplifier must be connected to an AC earthed mains
outlet that can delivered the maximum power required.
The use of extension cables or adaptors should be avoided
as this can jeoparadize correct power delivery to the
amplifier.
All connections must only be carried out or changed
with the amplifier switched OFF. Ensure proper
impedance matching while in use for BRIDGE mode
applications. For continuous safe operation, resultant
impedance of the speakers 8 ohm/4 ohm is recommen-
ded.
For 2 ohm/4 ohm applications, it is recommended
to use speakon connectors only. Use of cable 40/36
or thicker is recommended to prevent power
losses.
The level of input signal should not exceed the
specified input sensitivities. Excessive input signal
levels result in over driving of input circuit which
leads to saturated / distorted output at speaker
terminals.
Do not operate the amplifier with continuously
blinking CLIP LED. The respective volume control
of the channels must be adjusted so that the output
level does not clip and distort. Do not obstruct the
front or back of the amplifier for necessary intake of
air.