Questions and Answers

  • B
    Bobby CoxAug 18, 2025
    Why is water escaping from the overflow of my Stulz Humidifier?
    • H
      Heidi MorrowAug 18, 2025
      Water may escape from the overflow of your Stulz Humidifier for a couple of reasons: * The water supply float switch FS1 should close the supply valve when the maximum water level is reached. If the valve is open (e.g. clogging, mechanical fault), water is fed to the humidifier continuously. * If the drain is blocked, the flush valve is closed, or the unit is not correctly installed, water may escape from the overflow.
  • M
    Michael CooperNov 1, 2025
    What to do if my Stulz Humidifier has no mist production?
    • C
      Carolyn CruzNov 1, 2025
      If your Stulz Humidifier isn't producing mist, there are several things you can check: * Start up the unit and check the function of the control system. * Ensure the unit is getting electrical power. * Verify the control system parameters and reset if necessary, in case enabling or flush function is active, or the setpoint was reached. * Check the drinking water supply, fill valve, and drain to ensure a sufficient water supply. * Check float switches FS1 and FS2, and voltage to motherboard (CH) slot CN1 contact 1/2 and slot CN2 contact 5. * Check electrical supply H1/G1 and H2/G2. * Check the transformer. * Ensure the unit is installed correctly as described in the "Humidifier distance" section. * Check operating hours and visually inspect oscillators. * Check setpoint...

Summary

STULZ UltraSonic Humidifier Technical Manual

2. Safety

2.1. Proper use

Defines intended application and prohibitions.

2.2. Basic safety instructions

General safety precautions for operation and maintenance.

2.3. Qualification requirements for personnel

Specifies required qualifications for personnel.

4. Product description

4.3. Description of unit

Components and how the unit works.

4.5. Technical data

Key specifications and performance data.

4.7. Application limits

Operating conditions and material compatibility.

4.9. Water treatment

Requirements for water quality and treatment.

6. Open-loop and closed loop control

6.1. Master;slave control cabinet

Details on the control cabinet and its functions.

7. Installation

7.1. Installation diagram

Visual layout of connections and components.

7.2. Installation clearances

Required space around the unit for access.

7.3. In-duct installation

Procedures for mounting within air ducts.

7.4. Connecting water supply lines

Procedures for connecting water supply.

7.5. Electrical connection

How to connect power and wiring.

8. Start-up

9. Operation

11. Maintenance

15. Troubleshooting

Stulz ENS Series Specifications

General IconGeneral
InstallationWall-mounted or floor-standing
Steam GenerationElectrode boiler
Cylinder MaterialStainless steel
Safety FeaturesOverheating protection, water level monitoring
Power Supply400 V, 50/60 Hz
Steam TemperatureApproximately 100°C
Control Accuracy+/- 1% RH
MaterialStainless steel
Protection ClassIP20
Water QualityDemineralized or softened water