© STULZ GmbH, Hamburg DE / 06-2016 / 1000687
-
45
-
STULZ UltraSonic -System for duct humidication ENS 14 A - 18 A- Installation
ULTRASONIC
38
Copyright STULZ GmbH 02/1997
MONTAGE MODELLREIHE BNB
Wasserseitige Anschlüsse an den BNB-Befeuchtern. Die Lage der Anschlüsse und weitere
Geräteabmessungen finden Sie unter Punkt 2.2.
Wasserzuleitung
Überlauf
ULTRASONIC
38
Copyright STULZ GmbH 02/1997
MONTAGE MODELLREIHE BNB
Wasserseitige Anschlüsse an den BNB-Befeuchtern. Die Lage der Anschlüsse und weitere
Geräteabmessungen finden Sie unter Punkt 2.2.
Wasserzuleitung
Überlauf
7.4.2.1. Overview connection
Proceed as follows to connect the overow:
3
Connect the other end of the hose to the
local waste water system.
2
Use a clip to x the hose in place.
1
Push a drainage hose (inside diameter 15
mm) over the overow tting.
ULTRASONIC
38
Copyright STULZ GmbH 02/1997
MONTAGE MODELLREIHE BNB
Wasserseitige Anschlüsse an den BNB-Befeuchtern. Die Lage der Anschlüsse und weitere
Geräteabmessungen finden Sie unter Punkt 2.2.
Wasserzuleitung
Überlauf
Overow pipe 1/2", provided on site
ULTRASONIC
38
Copyright STULZ GmbH 02/1997
MONTAGE MODELLREIHE BNB
Wasserseitige Anschlüsse an den BNB-Befeuchtern. Die Lage der Anschlüsse und weitere
Geräteabmessungen finden Sie unter Punkt 2.2.
Wasserzuleitung
Überlauf
CAUTION
Using a safety tray.
If the humidier is mounted on a wall, the overow pipe must be connected for additional safety. How-
ever, no water ows into the overow during normal operation. If it is not possible to connect the
safety overow to the drain, install the humidier in the safety tray. (See section "7.3. Wall-mounted
installation" on page 34).
Note
CAUTION
Free overow.
The overow must not be closed while the unit is in operation.
IMPORTANT
Overow pipe 1/2", provided on site
CAUTION
No contact with waste water.
The overow must drain freely!
IMPORTANT
AIR INLET
MIST OUTLET
10
21 5
347
9
10
11
HUMIDIFIER CASING
ELIMINATER
METAL CONNECTOR
METAL CONNECTOR
WATER SUPPLY TUBE
OVERFLOW PIPE
DRAIN PIPE
MOUNTING FOOT
WATER SUPPLY VALVE
SUS304
ABS
4P
3P
TO BE PROVIDED BY USER
16mm O.D. 13mm I.D.
12mm O.D. 8mm I.D.
SUS304
TO BE PROVIDED BY USER
SPECIFICATIONS
MODEL
CAPACITY(kg/h)
NOS.OF ULTRASONIC
NEBULIZER UNIT
POWER SUPPLY
RATED POWER
CONSUMPTION(w)
WEIGHT(kg)
DIMENSION L(mm)
DIMENSION P(mm)
ENS14A
13~14
24
AC48V±10%
750
11
785
730 895
950
13
960
30
17~18
ENS18A
6
12
CORD(MAIN) SHIELD CABLE 4C 4m
CORD(CONTROL) SHIELD CABLE 3C 4m
ウエットマスター株式会社
CO LTDWETMASTER ,.
WETMASTER ENS
200
230
260
7
P
L
45 55 40
15
45
10 95 20 50
175
110 ≒60
30 60 20
15
50
ITEM
1
2
3
4
5
6
7
8
9
10
11
PART NAME SPEC./TYPE
30
12
RING AND NUT 6mm/6.35mm
8

Table of Contents