Electronic Control System
3-41
#7019014 - Revision A - October, 2010
Built-In (BI) Series
Built-In (BI) Series
Temperature Log NOTES:
• If Manual Compartment Disable Mode has been activated during any of the indexes, average temperatures will
continue to be logged, but no event indicator will appear with these temperatures.
• If the unit was in Showroom Mode during any of the indexes, average temperatures will continue to be logged, but
no event indicator will appear with these temperatures.
• If the unit was switched OFF by pressing the POWER key during any of the indexes and there was still power sup-
plied to the unit, the average temperatures will continue to be logged. This means temperatures would be expect-
ed to rise and the SERVICE indicator would be present in all indexes in which the unit was switched OFF.
• Temperature Log Recall Mode will end 20 seconds after the last key stroke.
Temperature Log Event Indicators - The diagrams below illustrate possible event indicators that may be
observed while in Temperature Log Recall Mode. (See Figures 3-76 through 3-78)
Figure 3-76. “bL” Indicates Index is “BLANK
” = No Temperature Logged Yet
(Only possible within first 5 days of unit operation, or after new control board is installed during service)
Index of occurrence (220 in this example)
“bL” = Blank
Figure 3-77. SERVICE Icon Illuminates = Unit was switched OFF During Index by Pressing POWER Key
Index of occurrence (82 in this example)
Indicates POWER key pressed, switching unit OFF
Figure 3-78. Bell Illuminates = Indicates Power Failure / Interruption During that Index Period