Suburban DynaPack A&E Manual 07/2019 Rev.6
20
INSTALLING AND SECURING UNIT TO WALL SLEEVE
Before installing and securing the unit to the wall sleeve, make sure that
the proper grille kit is installed. Due to the temperatures of the combustion
products released from the gas vent, DynaPack gas package units require the
use of an aluminum grille kit (see ACCESSORIES on page 36).
1. Double check the installation of the wall sleeve to make sure it is securely
attached to the wall opening. Inspect the wall sleeve drain for proper
installation if an inside drain is being used.
2. Examine the gaskets on the wall sleeve to make sure there is a continuous
seal between the wall sleeve and the unit.
3.
Place DynaPack unit onto the wall sleeve. Lift 3/4" and place over the wall
sleeve base (
see Figure 13
). A pallet jack works well for this. Temporarily block
the unit up and install front leveling bracket (
see Figure 13
). Adjust leveling
legs to level.
4. Use the two installation brackets and two straps to secure the unit to the
wall sleeve (see Figure 16). Verify that the gaskets of the wall sleeve make a
complete seal to the unit paying particular attention to top and bottom
corners of the unit to sleeve seal. Caulk if needed.
SECURING DYNAPACK TO WALL SLEEVE
FIGURE 16
AIR FILTER STANDARD
The DynaPack unit is equipped with a permanent, cleanable
air filter. This filter can be used if the unit is installed so that
the filter is accessible to the homeowner. The permanent filter
installed inside the unit must be removed and discarded if a
disposable filter is installed in the return air duct. See Table 3 for
the minimum filter area required for the DynaPack unit based
on unit capacity. It is recommended that air filters be cleaned
or replaced monthly to keep the cooling coil and interior duct
surfaces clean and able to operate most efficiently. Optional
MERV 13 filters are available.
TABLE 3
MINIMUM REQUIRED SURFACE AREA
FOR DISPOSABLE FILTERS -
S AND H SERIES
Model Number Filter Area
DYPA12
DYPA18
DYPA24
DYPA30
288 square inches
288 square inches
480 square inches
480 square inches
(continued on next page)

Other manuals for Suburban DynaPack S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban DynaPack S Series and is the answer not in the manual?

Suburban DynaPack S Series Specifications

General IconGeneral
BrandSuburban
ModelDynaPack S Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals