EasyManua.ls Logo

Sullair 32 250L Series - Section 2 SPECIFICATIONS; 2.1 SULLAIR SERIES 32 SPECIFICATIONS

Sullair 32 250L Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 2
SPECIFICATIONS
9
2.1 SULLAIR SERIES 32 SPECIFICATIONS
DIMENSIONAL:
Cooling Model Series Length Width Height Weight
In mm In mm In mm Ib kg
Water 32-250L 115 2920 90 2286 78 1980 8800 3990
32-300H 115 2920 90 2286 78 1980 8800 3990
Air 32-250L 115 2920 90 2286 78 1980 8600 3900
32-300H 115 2920 90 2286 78 1980 8800 3990
Remote 32 -250L 56 1425 58 1415 83 2110 1550 105
Air Cooler 32-300H 56 1425 58 1415 83 2110 1550 105
COMPRESSOR:
Typ e : Rotary Screw
Maximum Operating*: 110 PSI (L), 125 PSI (H)
Bearing Type : Anti- Friction
Ambient Temperature (Max) **: 105˚F(40˚C)
Cooling: Pressurized Coolant Fluid
Lubricant: 24Kr Coolant Fluid
Sump Capacity: 50 Gallons (189 Liters)
Control: Electro-Pneumatic
MOTOR:
Make: General Electric, Reliance, Westinghouse,
Lincoln, or Equal
Type: Open Dripproof, 460V, A.C., Three Phase, 60
Cycles, 40˚C Maximum Ambient Temperature
Options available: 200-230 and 575 volt/T.E.F.C. also available.
Size 250 and 300 HP
Starter 460V Full Voltage Magnetic
Options Available: 200-230 and 575 volt.
Speed 1770 RPM
* Special machines are available for operating at higher pressures.
** Special machines are available for operation in higher ambient temperatures.