Section 2
SPECIFICATIONS
9
2.1 SULLAIR SERIES 32 SPECIFICATIONS
DIMENSIONAL:
Cooling Model Series Length Width Height Weight
In mm In mm In mm Ib kg
Water 32-250L 115 2920 90 2286 78 1980 8800 3990
32-300H 115 2920 90 2286 78 1980 8800 3990
Air 32-250L 115 2920 90 2286 78 1980 8600 3900
32-300H 115 2920 90 2286 78 1980 8800 3990
Remote 32 -250L 56 1425 58 1415 83 2110 1550 105
Air Cooler 32-300H 56 1425 58 1415 83 2110 1550 105
COMPRESSOR:
Typ e : Rotary Screw
Maximum Operating*: 110 PSI (L), 125 PSI (H)
Bearing Type : Anti- Friction
Ambient Temperature (Max) **: 105˚F(40˚C)
Cooling: Pressurized Coolant Fluid
Lubricant: 24Kr Coolant Fluid
Sump Capacity: 50 Gallons (189 Liters)
Control: Electro-Pneumatic
MOTOR:
Make: General Electric, Reliance, Westinghouse,
Lincoln, or Equal
Type: Open Dripproof, 460V, A.C., Three Phase, 60
Cycles, 40˚C Maximum Ambient Temperature
Options available: 200-230 and 575 volt/T.E.F.C. also available.
Size 250 and 300 HP
Starter 460V Full Voltage Magnetic
Options Available: 200-230 and 575 volt.
Speed 1770 RPM
* Special machines are available for operating at higher pressures.
** Special machines are available for operation in higher ambient temperatures.