SECTION 2
®SULLAIR®
12
3700 Operator’s Manual and Parts List
Figure 2-4
1. Air Outlet
2. Pressure Regulator
3. Solenoid Valve
4. Air Inlet
5. Blowdown Valve
6. Minimum Pressure / Check Valve
7. Sump Tank
F i g u r e 2 - 4
Sequencing Control System
FULL LOAD MODE - 50 TO 100 PSIG (3.4 TO
6.9 BAR)
When the compressed air pressure rises above 50 psig
(3.4 bar), the minimum pressure valve opens allowing
compressed air to flow into the service line. From this
point on, the line air pressure is continually monitored by
the microprocessor controller. The pressure regulator
and the solenoid valve remain closed during this phase.
The inlet valve is in the fully open position as long as the
compressor is running at 100 psig (6.9 bar) or below.
MODULATING MODE - 100 TO 110 PSIG (6.9
TO 7.6 BAR)
If less than the rated capacity of compressed air is being
used, the service line pressure will rise above 100 psig
(6.9 bar). The pressure regulator valve gradually opens,
directing air pressure to the inlet control valve, reducing
air entering the compressor until it matches the amount
of air being used. The control system functions
continually in this manner between the limits of 100 to
110 psig (6.9 to 7.6 bar) in response to varying demands
from the service line.