P-11 Warmup setpt
0-500 Sec 130
P-12 Cooldn DLY
0-600 Sec 300/480
P-13 Min RPM
0-2000 RPM 1400
P-14 Max RPM
0-2000 RPM 1840
P-15 Min RPM DB
0-100 RPM 30
P-16 THR Min PULS
1-100 1
P-17 THR Max PULS
1-100 5
P-18 THR FDBK DLY
1-100 3
P-19 THR Sensitvy
1-1000 25
P-20 SP rate +
0-100 PSI 2
P-21 SP rate -
0-100 PSI 2
P-22 HI P1 AL
0-100 PSI 49
P-23 LO P3/P4 SD
0-50 PSI 30
P-24 HI P3/P4 SD
0-100 PSI 90
P-25 HI P3-P4 AL
0-100 PSI 20
P-26 HI T1 AL
0-500 F 435/443
P-27 HI T1 DLY SD
0-500 F 445
P-28 HI T1 SD DLY
0-100 Sec 10
P-29 HI T1 IMM SD
0-500 F 460
P-30 HI T2 AL
0-500 F 435/443
P-31 HI T2 DLY SD
0-500 F 445
P-32 HI T2 SD DLY
0-100 Sec 10
P-33 HI T2 IMM SD
0-500 F 460
P-34 HI T3 AL
0-200 F 160
P-35 HI T3 SD
0-200 F 165
P-36 HI T4 AL
0-500 F 155
P-37 HI T4 SD
0-500 F 160
P-38 HI T5 AL
0-500 F 155
P-39 HI T5 SD
0-500 F 160
P-40 LO P2 SD
-100-500 PSI 50
P-41
LO P2 DLY
This shutdown is a Class “P”
Shutdown and will begin timing
when the unit is loaded.
0-900 Sec 600
“P” Number Description Range Default Setting