DE-18 USER MANUAL SECTION 7
84
1. Detach the body from the bowl by twisting
the body about the bowl as far as it can go
(approximately 1/8 turn), and pulling apart.
2. At this time, unscrew the baffle from the
body. Remove the element.
3. Discard the element.
4. Replace the element with the new one found
in the repair kit, and reinstate into position on
the body stem. Replace baffle and tighten.
5. Loosen and remove the nut on the bottom of
the bowl.
6. Remove the float assembly and seals.
7. Replace the seals with those found in the
repair kit.
8. Replace those items in the float assembly
with those found in the repair kit.
9. Replace the float assembly into the bowl.
Tighten the nut.
10. Re-connect the body and bowl assemblies.
CONDENSATE DRAIN SOLENOID VALVE
(PIN 02250125-805)
MAINTENANCE
Refer to Figure 7-5. Solenoid valve (P/N 02250125-
805) maintenance is quite minimal but a periodic
cleaning of strainer (P/N 02250117-912) is desirable.
The time between cleanings will vary depending on
operating conditions. In general, if the voltage to the
coils is correct, sluggish valve operation or excessive
leakage will indicate that cleaning is required. If parts
replacement is required, order rebuild kit no.
02250125-840 (valve) and no. 02250125-854 (coil),
and follow the procedure explained below.
NOTE
Coat seals with same fluid as used in
compressor fill before installation to pro-
mote proper sealing.
WARNING
Turn off all power, relieve package pressure,
and disconnect coil lead wires to the valve
before making repairs. It is not necessary to
remove the valve from pipework for repairs.
*Replacement Kit P/N 02250125-840
**Replacement Coil P/N 02250125-854
Figure 7-5: Solenoid Valve
(P/N 02250125-805)