Section 4
INSTALLATION
14
power to the compressor disconnected (see Warn-
ing above). Drain t he fluid from the compressor us-
ing the compressor fluid drain cap (See Figure
2 --- 1 ) .
Fluid capacity for the compressor can be found in
Section 3, Specifications of this manual.
4.5 MOTOR ROTATION DIRECTION CHECK
After t he electrical wiring has been done, it is nec-
essary to check the direction of motor rotation.
When looking at the motor from the cooler end of
the compressor unit, the cooler fan should be turn-
ing clockwise. If t he motor is not turning clockwise,
disconnect power to the starter and exchange any
two of the three power input leads, then check rota-
tion.
A direction of rotation decal is located on the motor
shroud, n ext to the cooler to insure correct motor/
compressor rotation.
4.6 ELECTRICAL PREPARATION
Interior electrical wiring is performed at the factory.
Required customer wiring is minimal, but should
be done by a qualified electrician in compliance
with OSHA, National Electrical Code, and any other
applicable State, F ederal and local electrical codes
concerning isolation switches, fused disconnects,
etc. Sullair provides a wiring diagram for use by the
installer.
A few electrical checks should be made to help as -
sure that the first start---up will be trouble---free.
WARNING
!
Lethal shock hazard inside. Disconnect all power
at source before opening or servicing.
1. Check incoming voltage. Be sure that compres-
sor is wired for the correct incoming voltage.
2. Check starter for correct size, proper overload
relay and heaters.
3. Check a ll electrical connections for tightness.