Sullair LS-32 - Troubleshooting Guide; Supervisor Controller

Sullair LS-32
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 5
SUPERVISOR CONTROLLER™
32
ALL
ALL
ALL
ALL
ALL
ALL
FLOODED
ALL
ALL
FLOODED
FLOODED
FLOODED
ALL
FLOODED
ALL
FLOODED
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS
Main Motor Overload
(continued)
I/O Mod Com Error,
Com Mod Com Error,
Motor Mod Com Error
Oil Filter Maint., dP2 Oil
Filter High
P3 Oil Pressure Low,
P3 Oil Pressure Low,
dP3 Oil Pressure Low
P1 Sensor Fail, P2
Sensor Fail, P3 Sensor
Fail, P4 Sensor Fail, T1
Sensor Fail, T2 Sensor
Fail, T3 Sensor Fail, T4
Sensor Fail, T5 Sensor
Fail
dP1 Separator Maint.
P1-P2
Factory Setup Error
P1 Sump Pressure High
Module Network Error; The
Network that Connects the
Display Module, I/O Module and
Other Optional Modules is Not
Working Correctly
Pressure Across Oil Filter
Above 20 psi (1.4 bar) while
running
Oil Pressure Low
Sensor or Wiring Failure
Pressure Across Separator High
The Factory Setup Information
Needs to be Reviewed for
Correct Values
Sump Pressure High
Make sure unload pressure set
below limit of compressor
Check motor starter contacts for
proper operation.
Check line voltage, if low consult
power company.
Check wiring.
Replace module referred to in error
message, if problem persists
replace display module.
Oil filter clogged, replace oil filter.
Low ambient temperature, sump
heater may be required in ambients
below 40°F (4°C).
Sensor failure, check sensor, wiring
and tubing.
Oil pump failure, consult Sullair
service department.
Oil filter clogged, replace filter.
Sump oil level low, replenish oil to
proper level.
Low ambient temperature, sump
heater may be required in ambients
below 40°F (4°C).
Oil pump may be required for
remote coolers.
Check sensor wiring.
Check sensor.
Plugged separator elements,
replace.
Pressure sensor failure, check sen-
sor wiring.
If problem persists replace
Supervisor.
Sullicon, spiral or blowdown valve
failed, check valves.
5.13 TROUBLESHOOTING GUIDE- SUPERVISOR CONTROLLER (CONTINUED)
MESSAGE MODEL ENABLE PROBABLE CAUSE REMEDY