SRL Service Manual
Revision 00
July 2007
Page 60 of 56
13.1 Correction Factors
Ambient Temperature Correction Factor (A)
Ambient Temperature (
o
F) 60 70 80 90 100 110 113
Correction Factor “A 1.30 1.23 1.16 1.08 1 0.92 0.89
Air Inlet Temperature Correction Factor (B)
Air Inlet Temperature (
o
F) 90 100 110 120 130 140
Correction Factor “B” 1.26 1 0.80 0.63 0.50 0.38
Air Inlet Pressure Correction Factor (C)
Ambient temperature (
o
F) 50 80 100 125 150 170 190 200
Correction Factor “C” 0.76 0.93 1 1.03 1.11 1.14 1.16 1.17