2.3 Technical Specifications
2.3.1 60 Hz Air Cooled Models
SRL-250
SRL-325
SRL-400
SRL-500
SRL-700
SRL-800
SRL-1000
SRL-1200
Type --
Charge lb (kg) 3.26 (1.48) 5.07 (2.3) 5.29 (2.4) 5.95 (2.7)
13.23 (6) 14.33 (6.5)
Quantity Qty
Internal Diameter mm
Length mm 1500 900
2800 2000
Min psig (barg)
Max psig (barg)
Min °F (°C)
Max °F (°C)
Min °F (°C) 131 (55) 104 (40) 99 (37) 99 (37) 104 (40) 118 (48)
Max °F (°C) 167 (75) 149 (65) 144 (62) 149 (65) 140 (60) 154 (68)
Min °F (°C)
Max °F (°C)
On psig (barg)
Off psig (barg)
Qty
psig (barg)
-- (Note 1)
Code
All parameters refer to operating conditions at zero air flow.
Note 1 - Available in 230/1/60, 230/3/60 or 460/3/60.
SRL-1400
SRL-1600
SRL-2000
SRL-2400
SRL-3000
SRL-3800
SRL-5000
SRL-6000
Type --
Charge lb (kg) 19.84 (9) 22.05 (10) 27.12 (12.3) 25.35 (11.5) 40.79 (18.5) 42.99 (19.5) 61.73 (28) 68.34 (31)
Quantity Qty 456
Internal Diameter mm
Length mm 2800 1000 2300 2500
Min psig (barg)
Max psig (barg)
Min °F (°C)
Max °F (°C)
Min °F (°C) 113 (45)
Max °F (°C) 158 (70) 167 (75) 158 (70)
Min °F (°C)
Max °F (°C)
On psig (barg)
Off psig (barg)
Qty 456
psig (barg)
--
Code
All parameters refer to operating conditions at zero air flow.
R407C
35.6 (2)
48.2 (9)
33.8
(
1
)
66.7 (4.6)
Control Software Release
dt.3
460V / 3ph / 60 Hz
406 (28)
203 (14)
276 (19)
41 (5)
High Pressure Switch Setting
Standard Supply Voltages Available
Number of Heat Exchangers 2 3
Dew point temperature
Fan Pressure Switch
Discharge Temperature
131 (55) 131 (55)
167 (75) 167 (75)
2100
4000
Hot Gas Valve Setting
62.4
4.3
23
3.18
4
Refrigerant
dt.3
230 or 460V / 3ph / 60 Hz
Control Software Release
167 (75)
131
(
55
)
High Pressure Switch Setting
Standard Supply Voltages Available 460V / 3ph / 60 Hz
406 (28)
Dew point temperature
Number of Heat Exchangers
Fan Pressure Switch
Discharge Temperature
Expansion Capillaries
Suction Temperature
Hot Gas Valve Setting
Suction Temperature
66.7 (4.6)
62.4 (4.3)
48.2 (9)
33.8
(
1
)
1500
Refrigerant
9.92 (4.5)
Expansion Capillaries
3.18 4
R407C
1
2.5
2500
41 (5)
1
35.6
(
2
)
203 (14)
276 (19)

Table of Contents

Other manuals for Sullair SRL-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sullair SRL-2000 and is the answer not in the manual?

Sullair SRL-2000 Specifications

General IconGeneral
BrandSullair
ModelSRL-2000
CategoryDehumidifier
LanguageEnglish

Related product manuals