EasyManua.ls Logo

Sulzer XFP 155J-CB2 - User Manual

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
www.sulzer.com
Installation, Operating and Maintenance Instructions
Submersible Sewage Pump Type ABS XFP PE1-PE3
en
6005675 (11.08.2021)
EN 5675-L

Table of Contents

Questions and Answers

  • D
    Daniel EvansAug 5, 2025
    Why is my Sulzer Water Pump making excessive noise or vibration?
    • M
      manuel32Aug 5, 2025
      Excessive noise or vibration in your Sulzer Water Pump can stem from several causes. It could be due to a defective bearing, which would require bearing replacement. Another cause might be a clogged impeller; in this case, you should remove and clean the hydraulics. Also, check for the wrong direction of rotation and change it by interchanging two phases of the power supply cable.
  • D
    Darrell EdwardsAug 9, 2025
    What to do if my Sulzer Water Pump has low head or flow?
    • P
      Philip FoxAug 9, 2025
      If your Sulzer Water Pump exhibits low head or flow, there are a few things to investigate. First, check for the correct direction of rotation and change it by interchanging two phases of the power supply cable if needed. Also, the gap between the impeller and bottom plate might be too wide, reduce the gap. Finally, ensure the gate valve is fully open; a partially open valve can restrict flow.
  • A
    Abigail MataAug 14, 2025
    Why does my Sulzer Water Pump switch on and off intermittently?
    • R
      Rhonda EspinozaAug 14, 2025
      Intermittent switching of your Sulzer Water Pump can be attributed to a few reasons. If it's due to a temperature sensor shutdown, the motor will restart automatically once the pump cools down. Also, check the thermal relay settings in the control panel. Impeller blockage can also cause this issue, so inspect for that. If none of these resolve the problem, a service inspection is required.
  • A
    Ashley FoxAug 18, 2025
    What to do if the impeller is jammed in my Sulzer Water Pump?
    • L
      Lisa HuffAug 18, 2025
      If the impeller of your Sulzer Water Pump is jammed, you should inspect and remove any object causing the jam. Additionally, check the gap between the impeller and the bottom plate, adjusting it if necessary.
  • M
    michelle90Aug 22, 2025
    What to do if the gate valve is closed or the non-return valve is blocked in my Sulzer Water Pump?
    • G
      Gary CunninghamAug 22, 2025
      If you find that the gate valve of your Sulzer Water Pump is closed or the non-return valve is blocked, open the gate valve and clean any blockage from the non-return valve.
  • J
    Joel WolfeAug 27, 2025
    What to do if there is level control override in my Sulzer Water Pump?
    • P
      Pamela BarberAug 27, 2025
      If there is a level control override in your Sulzer Water Pump, check for a float switch that is faulty or tangled and held in the OFF position in the sump.
  • T
    Theresa NelsonAug 31, 2025
    How to remove air lock in volute of Sulzer Water Pump?
    • M
      Maria BlackAug 31, 2025
      To remove an air lock in the volute of your Sulzer Water Pump, shake or raise and lower the pump repeatedly until resulting air bubbles no longer appear at surface level.

Summary

Safety

3.1 Personal Protective Equipment

Lists mandatory and recommended personal protective equipment for safe operation.

Ex Zone Motor Operation

4.1 Explosion-Proof Approvals

Details the explosion-proof ratings and standards for the motors.

4.4 Operation with Frequency Inverters in Hazardous Areas

Guidelines for operating Ex pumps with frequency inverters in hazardous zones.

Technical Data and Nameplates

Lifting, Transport and Storage

8.1 Lifting

Guidelines and safety precautions for lifting the pump.

Mounting and Installation

9.3 Installation Types

Describes different methods for installing the pump.

Electrical Connection

Commissioning

Maintenance and Service

12.9 Clearing Pump Blockage

Instructions for operators and service personnel to resolve pump blockages.

Troubleshooting Guide

Sulzer XFP 155J-CB2 Specifications

General IconGeneral
Product nameSulzer XFP 155J-CB2
CategoryWater Pump
Maximum submersion depth20 m
Speed1450 rpm
Outlet Diameter80 mm
Motor size155 mm
Discharge size80 mm

Related product manuals