Do you have a question about the Sulzer ABS XFP-PE4 and is the answer not in the manual?
Type | Submersible Sewage Pump |
---|---|
Maximum submersion depth | 20 m |
Material | Cast iron |
Outlet size | 80 mm |
Liquid temperature | 0°C to 40°C |
Application | Wastewater, sewage |
Operating Temperature | 0°C to 40°C |
Instructions for correct product usage and actions for faults.
Details applications and suitable liquids for XFP submersible sewage pumps.
Details applications and suitable liquids for AFLX mixed flow column pumps.
Details applications and suitable liquids for VUPX submersible propeller pumps.
Provides technical specifications, noise levels, and dimension drawing links.
Explanation of data on standard, ATEX, and CSA/FM nameplates.
General and specific health and safety hints for Sulzer products.
Guidelines and precautions for safely lifting Sulzer units and components.
Details on protecting motor connection cables during transport.
Requirements and precautions for storing Sulzer products properly.
Lists and details available monitoring options for motors.
Explanation of the leakage sensor's function and immediate actions upon activation.
Description of stator thermal protection using bimetallic limiters or PTC/PT100 sensors.
Details on bimetallic, PTC, and PT100 sensors for temperature monitoring.
Guidelines for operating pumps with frequency inverters, including EMC and speed limits.
Details installation options for XFP submersible sewage pumps.
Procedure for fitting the pedestal, o-ring, and guide piece for XFP pumps.
Table of tightening torques for Sulzer stainless steel screws.
Details installation options and examples for AFLX and VUPX pumps.
Instructions for lowering AFLX/VUPX pumps and managing connection cables.
General information on electrical connection requirements and safety.
Details lead designations for direct starting in star and delta configurations.
Procedure for checking the pump's direction of rotation during commissioning.
Explanation of how to connect control circuit leads for submersible pumps.
Guides for connecting seal monitoring units to the control panel.
Details connection and configuration of external leakage sensors.
Instructions on how to correctly connect the EMC cable.
Checks and functional tests required before commissioning the pump/station.
Introduction to maintenance procedures and general tips for Sulzer pumps.
Advice for pumps that have been idle for extended periods.
Covers inspection intervals and checks for inspection and motor chambers.
Explanation of symbols used for oil filling/draining and visual inspection.
Details the oil filling and emptying procedure for XFP PE4/PE5 pumps.
Details the oil filling and emptying procedure for VUPX/AFLX pumps.
Provides oil quantities for inspection chambers based on motor size.
Lists lubricant filling quantities for seal chambers of PE3/PE4/PE5 pumps.
Lists lubricant filling quantities for seal chambers of VUPX/AFLX PE6 pumps.
Explanation of symbols for coolant/oil filling and visual inspection.
Details coolant/oil filling and emptying for XFP PE4/PE5 with cooling jacket.
Details coolant/oil filling and emptying for XFP PE6 with cooling jacket.
Provides reference values for antifreeze concentration and temperature.
Lists coolant filling quantities for XFP PE4 pumps by model.
Lists coolant filling quantities for XFP PE5 pumps by model.
Lists coolant filling quantities for XFP PE6 pumps by model.
Specifies allowable starting frequency per hour for motors.
Details removal procedures for XFP, AFLX, and VUPX submersible pumps.