Disable screwdriver when error occurred.
1~9
Setting value “1” means the screwdriver will be locked
when an error occurs.
Setting value “2” means when two consecutive errors
occurs will lock the screwdriver.
Setting value “3” means when three consecutive errors
occurs will lock the screwdriver…and so on. If the
tightening status is OK once, it will be recalculated。
ON: When malfunction signal『NS』 happens, it will
disable screwdriver immediately;User need to press
『ENTER』button to deactivate rotation(For I/O part.
But screwdriver can reverse.)
OFF: When malfunction『NG』happen, screwdriver
will not stop;it will not affect next activation. It will
provide a warning
Disable screwdriver when batch completed
ON: Stop screwdriver after batch completed. Users need
to press『ENTER』(For I/O part, it is confirm signal)
OFF: Screwdriver is normal after batch completed.