8
6. Screw setting
Name
Set Up
Value
Function Description
Default
setting
Tightening Program
01~99
Setup screw parameter.
01
Screw Name
******
Setup screw parameter name. It can choose
numbercapitals and lower case lettersnumber.
******
Step 1
001~250
Setup 1
st
sequence
01
Step 2
000~250
Setup 2
nd
sequence
00
Step 3
000~250
Setup 3
rd
sequence
00
Step 4
000~250
Setup 4
th
sequence
00
Step 5
000~250
Setup 5
th
sequence
00
OKALL Alarm Time
0.0~9.9
ATOKALL signal holding time
1.0
OK Time
0.0~9.9
OTOK signal holding time
9.9
NG Stop
OFF
1~9
Disable screwdriver when error occurred.
1~9
Setting value “1means the screwdriver will be locked
when an error occurs.
Setting value 2means when two consecutive errors
occurs will lock the screwdriver.
Setting value 3means when three consecutive errors
occurs will lock the screwdriverand so on. If the
tightening status is OK once, it will be recalculated
ON: When malfunction signalNS happens, it will
disable screwdriver immediatelyUser need to press
ENTERbutton to deactivate rotation(For I/O part.
But screwdriver can reverse.)
OFF: When malfunctionNGhappen, screwdriver
will not stopit will not affect next activation. It will
provide a warning
OFF
OKALL Stop
OFF/ON
Disable screwdriver when batch completed
ON: Stop screwdriver after batch completed. Users need
to pressENTER(For I/O part, it is confirm signal)
OFF: Screwdriver is normal after batch completed.
OFF
7. Extra function
Name
Function Description
Export to SD Card
Export to controller internal setting value(Controller settingProgram settingScrew setting)
Calibrate Tool
Calibration mode