EasyManua.ls Logo

Sumitomo HC-4E1 - MAINTENANCE; Maintenance Safety Precautions

Sumitomo HC-4E1
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
35
AVOID INJURY. Disconnect gas lines only when the compressor is stopped.
Disconnecting the cold head while it is cold may create excessively high internal
pressure as the gas warms. Material failure and uncontrolled pressure release
can cause serious injury.
AVOID INJURY. The compressor is charged with helium gas. Vent the
compressor to atmospheric pressure before disassembly, except when
disconnecting adsorber or the gas lines. Uncontrolled pressure release can
cause serious injury.
AVOID INJURY. Never use compressed helium gas from a cylinder without a
proper regulator. Overpressure can cause serious injury if the system equipment
ruptures.
AVOID INJURY FROM BURNS. During operation, some surfaces in the
compressor capsule become hot. Allow the compressor to cool for 1/2 hour after
shutdown before removing the cover for maintenance.
AVOID INJURY. When handling pressurized gas lines and other pressurized
equipment, always wear eye protection. Never apply heat to a pressurized gas
line or other pressurized components.
PRESERVE YOUR WARRANTY. Modification to equipment without the consent
of the manufacturer will void the warranty.
AVOID CONTAMINATION. Follow the charging and venting procedure to
prevent reversed flow of system gas. Do not charge through the supply coupling.
Do not vent through the return coupling. Reversed flow can contaminate the
system with compressor oil.

Table of Contents

Related product manuals