7
HALF-MASK RESPIRATORS Order Number
Silicone SR 100, Large/X-Large H01-2821
Silicone SR 100, Medium/Large H01-2021
Silicone SR 100, Small/Medium H01-2121
TPE SR 90-3 Medium/Large H01-2621
TPE SR 90-3 Small/Medium H01-2721
FILTER/CARTRIDGES/PRE-FILTER
OV Cartridge, SR 218-6 H02-2121
CL/HC/SD/FM Cartridge, SR 231 H02-3621
OV/SD/CL/HC/HF Cartridge, SR 232 H02-3721
AM/MA Cartridge, SR 229 H02-4321
P100lterSR510 H02-1321
Pre-filter, SR 221 H02-0121
SPARE PARTS
Cradle Head Harness R01-2002
Head Strap Pad R01-2001
Valve Flap Kit R01-2004
(2 exhalation, 1 Inhalation, 2 protective caps)
ACCESSORIES
Cleaning Wipes H09-0401
Protective Tyvek Hood H09-0321
Chemical Splash Hood H09-1021
Pre-lterholder R01-0605
Pre-lterholder5153-2 R01-0604
TestdiscSR322(forpre-lterholder5153-2) R01-0303
Storage Box H09-3021
Fit Check Adapter T01-1202
Permanent ID-tag R09-0101
Spark Arrester, SR 336 T01-2001
SmallTalk Voice Amplifier, ST2-SR T01-1219
PROTECTIVE ELEMENTS
The protective elements for the Sundström half-mask respirators are (4) four NIOSH approved chemical
cartridges and a P100 particle filter. A pre-filter designed to reduce nuisance dusts is also an optional
accessory for use with all protective elements.
Chemical Cartridges
A chemical cartridge absorbs and adsorbs specific vapors and gases from a contaminated atmosphere.
This process continues until the sorbent becomes saturated and allows the contaminant to ‘break-
through’thecartridgeandtobedetectedbytheuser.Eachchemicalcartridgeisdesignedtoprovide
protection only from specific contaminants. Replace chemical cartridges immediately when you detect
any contaminants inside the respirator.