121
Parameters SH8T SH10T
THDV(@Linear load)
< 2%
Backup switch time
<10ms
Rated output power
8000 W / 8000 VA 10000 W / 10000 VA
Peak output power **
13500 W / 13500 VA,10s 15000 W / 15000 VA,10s
Rated output current for
backup load during on grid
mode
43000 W / 43000 VA (25℃)
Efficiency
Max. efficiency / European
efficiency
98.0 % / 97.4 % 98.0% / 97.5 %
Protection & Function
Grid monitoring
Yes
DC reverse polarity
protection
Yes
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch (solar) Yes
Surge Protection DC Type II / AC Type II ***
PID Zero Yes
Parallel operation on grid port Master-slave mode
Battery input reverse polarity
protection
Yes
General Data
Topology (solar / battery) Transformerless / Transformerless
Degree of protection IP65
Dimensions (W x H x D) 620 * 480 * 195 mm
Weight 32kg
Mounting method Wall-mounting bracket
Operating ambient tempera-
ture range
-25 ℃ - 60 ℃
Allowable relative humidity
range(Non-condensing)
0% - 100%
Cooling method Natural convection
Max. operating altitude 2000m
Noise(Typical) 35dB(A)
Display LED
Communication
RS485, WLAN, Ethernet, CAN
DI / DO DI * 4 / DO * 2 / DRM0
User Manual 11 Appendix