116
Color Change
NO. CORRECTIONMEANINGERROR MESSAGE
Needle Position The needle bar did not reach
the right location during the
color change.
Turn the needle bar manually
until correct one is in stitching
position.
300
Repetition
NO. CORRECTIONMEANINGERROR MESSAGE
Repeat setting error (X and Y
less than 99)
Repetition exceeds limit. Reset so that X and Y are
greater than 99.
501
Encoder
NO. CORRECTIONMEANINGERROR MESSAGE
Encoder A signal is static.
Encoder Z signal is static.
There is an error on the A
encoder.
There is an error on the Z
encoder.
Be certain the encoder cable is
connected; turn machine off
and on again.
Be certain the encoder cable is
connected; turn machine off
and on again.
400
401