Output 1 only can be set.
[FX-301(P)(-HS) Code Setting Table]
STD
STD
STD
LONG
LONG
LONG
FAST
FAST
FAST
S-D
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
Direct
code
Check Check Check
Check
First digit
Response
Time
Hysteresis
Direct
code
L-ON
L-ON
L-ON
L-ON
D-ON
D-ON
D-ON
D-ON
L-ON / D-ON
Incident light intensity
%
Peak hold
Bottom hold
Incident light intensity
%
Peak hold
Bottom hold
Second digit
Display
Direct
code
ON
ON
ON
ON
OFF
OFF
OFF
OFF
NON (without timer)
OFF-delay
ON-delay
ONE SHOT
NON (without timer)
OFF-delay
ON-delay
ONE SHOT
Third digit
Adjust
lock
Timer operation
OFF
1 ms
3 ms
5 ms
10 ms
30 ms
50 ms
100 ms
300 ms
500 ms
1 sec.
2 sec.
3 sec.
4 sec.
5 sec.
Direct
code
Fourth digit
Timer
period
[FX-305(P) Code Setting Table]
STD
STD
STD
LONG
LONG
LONG
FAST
FAST
FAST
H-SP
U-LG
STDF
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
H-03 (large)
H-01 (small)
H-02 (standard)
H-02 (standard)
H-02 (standard)
Direct
code
Check Check Check
Check
First digit
Response
Time
Hysteresis
Direct
code
L-ON
L-ON
L-ON
L-ON
D-ON
D-ON
D-ON
D-ON
L-ON / D-ON
Incident light intensity
%
Peak hold
Bottom hold
Incident light intensity
%
Peak hold
Bottom hold
Second digit
Display
Direct
code
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
NON (without timer)
OFF-delay
ON-delay
ONE SHOT
NON (without timer)
OFF-delay
ON-delay
ONE SHOT
ON-delay OFF-delay
ON-delay ONE SHOT
ON-delay OFF-delay
ON-delay ONE SHOT
Third digit
Adjust
lock
Timer operation
OFF
1 ms
3 ms
5 ms
10 ms
30 ms
50 ms
100 ms
300 ms
500 ms
1 sec.
2 sec.
3 sec.
4 sec.
5 sec.
Direct
code
Fourth digit
Timer
period
* In the event that the timer operation for ON-delay / OFF-delay or
ON-delay / ONE SHOT (8~b) are both set using the 3rd digit, then
the timer period setting selected by the 4th digit will be common to
both timer operations.
PRO5 Mode
9-1. PRO5 Mode Functions and Settings
9
Direct Code
PRO5 mode allows the input of direct codes and adjust lock functions.
It also permits the unit to be reset (re-initialized).
Furthermore, the interference prevention function can be set for FX-305(P).
FX-301(P)(-HS) and FX-305(P) contain certain encoded basic configuration information that can be set by inputting a 4-digit code.
The functions that may be set using direct coding are: Response time, Hysteresis, L-ON / D-ON, Display setting,
Adjust lock setting function, Timer operation and Timer period.
:
Code Setting Function
The following input of a 4-digit code allows the configuration to be set directly,
without the need to set each individual function.
Refer to p.51 for setting procedure