EasyManua.ls Logo

Superior VRT3542WH - Massachusetts State Requirements; Massachusetts Installation Requirements

Superior VRT3542WH
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE:DIAGRAMS&ILLUSTRATIONARENOTTOSCALE.
5
NOTE: The following requirements reference various Massachusetts
and national codes not contained in this document.
Requirements for the Commonwealth of Massachusetts
TheseappliancesareapprovedforinstallationintheUSstateofMas-
sachusettsifthefollowingadditionalrequirementsaremet:
• Un-ventedRoomHeatersshallbeinstalledinaccordancewith527
CMR30.
• Installationandrepairmustbedonebyaplumberorgastterlicensed
intheCommonwealthofMassachusetts.
• Theexiblegaslineconnectorusedshallnotexceed36inches(92
centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• UnventedappliancesmayNOTbeinstalledinbedroomsorbathrooms.
• A working smoke detector must be installed in the area where vent-
free appliances are installed.
Sellerofunventedpropaneornaturalgas-redsupplementalroomheaters
shallprovidetoeachpurchaseracopyof527CMR30uponsaleoftheunit.