Chapter 5: Advanced Serverboard Setup
5-155-14
SUPERSTORAGESYSTEM 6038R-E1CR16H User's Manual
Reset Button
The Reset Button connection is
located on pins 3 and 4 of JF1 and
attaches to the reset switch on the
computer chassis. See the table on
the right for pin denitions.
Power Button
The Power On connection is on pins
1 and 2 of JF1. These should be con-
nected to the chassis power button.
Momentarily contacting both pins will
power on/off the system. To turn off
the power when the system is on,
press the button for 4 seconds or
longer. See the table on the right for
pin denitions.
5-8 Connector Denitions
ATX Power 24-pin Connector
Pin Denitions
Pin# Denition Pin # Denition
13 +3.3V 1 +3.3V
14 -12V 2 +3.3V
15 COM 3 COM
16 PS_ON 4 +5V
17 COM 5 COM
18 COM 6 +5V
19 COM 7 COM
20 Res (NC) 8 PWR_OK
21 +5V 9 5VSB
22 +5V 10 +12V
23 +5V 11 +12V
24 COM 12 +3.3V
Reset Button
Pin Denitions (JF1)
Pin# Denition
3 Reset
4 Ground
Power Button
Pin Denitions (JF1)
Pin# Denition
1 Power Signal
2 Ground
Secondary Power Connector
JPWR1 and JPWR2 must also be
connected to the power supply. See
the table on the right for pin deni-
tions.
Required Connection
+12V 8-pin Power
Pin Denitions
Pins Denition
1 - 4 Ground
5 - 8 +12V
Warning: To provide adequate power supply to the serverboard, be sure to connect
J24 and both JPWR1 and JPWR2 to the power supply. Failure to do so will void
the manufacturer warranty on your power supply and serverboard.
Power Connectors
A 24-pin main power supply connec-
tor (J24) and two 8-pin CPU power
connectors (JPWR1/JPWR2) must be
connected to the power supplyto pro-
vide adequate power to the system.
These power connectors meet the SSI
EPS 12V specication. See the table
on the right for pin denitions.
Overheat, Fan/Power Fail/UID LED
Connect an LED cable to pins 7 and
8 of the front control panel to use the
Overheat/Fan Fail/Power Fail and
UID LED connections. The red LED
on pin 8 provides warnings of over-
heat, fan failure or power failure. The
blue LED on pin 7 works as the front
panel UID LED indicator. Refer to the
table on the right for pin denitions.
HDD LED/UID Switch
The HDD LED connection is located
on pins 13 and 14 of JF1. Attach a
cable to pin 14 to show HDD activity
status. Attach a cable to pin 13 to use
UID switch. See the table on the right
for pin denitions.
NIC2 LED
Pin Denitions (JF1)
Pin# Denition
9 Activity
10 Link
HDD LED
Pin Denitions (JF1)
Pin# Denition
13 UID Switch
14 HD Active
NIC2 (LAN2) LED
The LED connections for LAN2 are
on pins 9 and 10 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
denitions.
NIC1 LED
Pin Denitions (JF1)
Pin# Denition
11 Activity
12 Link
NIC1 (LAN1) LED
The LED connections for LAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
denitions.
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
denitions.
PWR Fail LED
Pin Denitions (JF1)
Pin# Denition
5 3.3V
6 PWR Supply Fail
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin Denitions (JF1)
Pin# Denition
7 Blue_UID LED
8 OH/Fan Fail/Power Fail
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Denition
Off Normal
On Overheat
Flashing Fan Fail