SuperServer 2049U-TR4 User's Manual
22
Note: Both front chassis rails and the rack rails have a locking tab, which serves two functions.
First, it locks the server into place when installed and pushed fully into the rack (its normal
operating position. In addition, these tabs lock the server in place when fully extended from
the rack. This prevents the server from coming completely out of the rack when pulled out
for servicing.
Warning: Stability hazard. The rack stabilizing mechanism must be in place, or the
stabilize the rack can cause the rack to tip over.
Figure 2-5. Extending and Mounting the Outer Rails
Installing the Outer Rails onto the Rack
Installing the Outer Rails
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks on the front of the outer rail onto the square holes on the front of the
rack. If desired, use screws to secure the outer rails to the rack.
4.
the rack.
5. Hang the hooks of the rear section of the outer rail onto the square holes on the rear of
the rack. Take care that the proper holes are used so the rails are level. If desired, use
screws to secure the rear of the outer rail to the rear of the rack.
6. Repeat for the other outer rail.
1
4
3
2
21D01
L-min=676.00(26.61")(outer rail)