SuperServer 2049U-TR4 User's Manual
48
Figure 3-11. Installing a Drive into the Carrier
Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive carrier
displays two status LEDs on the front of the carrier.
LED Color State Status
Activity LED
Blue Solid On SAS/NVMe drive installed
Blue Blinking I/O activity
Status LED
Red Solid On Failed drive for SAS/SATA/NVMe with RSTe support
Red Blinking at 1 Hz Rebuild drive for SAS/SATA/NVMe with RSTe support
Red Blinking with two blinks and
one stop at 1 Hz
Hot spare for SAS/SATA/NVMe with RSTe support
Red Power on for SAS/SATA/NVMe with RSTe support
Red Blinking at 4 Hz Identify drive for SAS/SATA/NVMe with RSTe support
Green Solid On Safe to remove NVMe device
Amber Blinking at 1 Hz Attention state—do not remove NVMe device
System Cooling
Replacing a System Fan
Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fan will
ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace
any failed fan at your earliest convenience with the same type and model (the system can
continue to run with a failed fan).
Remove the top chassis cover while the system is still running to determine which of the fans
has failed. Then power down the system before replacing a fan. Removing the power cord(s)
is also recommended as a safety precaution.