MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurences that
a duplicate event must happen before the MECI counter is incremented. This is a numeric
value. The default value is 1.
METW
The Multiple Event Time Window (METW) denes the number of minutes that must pass
between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99.
The default value is 60.
Note: After making changes on a setting, be sure to reboot the system for the changes
to take effect.