EasyManua.ls Logo

Supmeter BST106-N59 - Working Specifications; 9.1 Brief Description

Supmeter BST106-N59
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
9. Working Specifications
9.1 Brief Description
Check oil pressure sensors and position sensor before starting the wheel loader.
Start the wheel loader, then lift the lift-arm and bucket for 5~10 times to preheating the hydraulic
oil.
BUCKET-UP: Flip the bucket upward to the limit position.
ARM-DOWN: Put the lift-arm down so that the bucket goes down to the lowest position.
Turn the power switch of weighing indicator on.
Press keyZerofor Zero Calibration.
Confirm if there is a need to do System Clibration and Loading Verification.
After Loading Verification, press keyClsto Clear Screen without saving Loading Record.
Press keyPauseto enter Pause state with red sign displaying, and then let the bucket go
down to the lowest position.
Set Setpoint Parameters.
Press keyLoadto enter loading state with the blue sign ‘▲’ displaying.
After shoveling materials into the bucket, flip the bucket upward to the limit position.
After the wheel loader reached the loading position with relatively flat ground, lift the lift-arm
and bucket with accelerating for weighing.
Once alarm occurs, press key Void to Cancel Totalizing, then lift the lift-arm and bucket for
weighing again.
After weighing finished, flip the bucket downward for discharging materials.
After Totalized Loading Weight reached setpoint, press key Finish to save and print Loading
Record, and Clear Screen automatically after Loading process finished.
Before going off work, turn the power switch of weighing indicator off at first, then turn the
power switch of wheel loader off.