SV1000K3 23
INJECTOR + FUEL PUMP + FUEL PRESSURE REGURATOR
FI-SENSORS
ITEM SPECIFICATION NOTE
Injector resistance 11 – 13 Ω at 20 °C (68 °F)
Fuel pump discharge amount 168 ml and more (5.7/5.9 US/lmp oz)
for 10 seconds at 300 kPa (3.0 kgf/cm
2
, 43 psi)
Fuel pressure regulator operat-
ing set pressure
Approx. 300 kPa (3.0 kgf/cm
2
, 43 psi)
ITEM SPECIFICATION NOTE
CMP sensor peak voltage 3.7 V and more
CKP sensor resistance 130 – 240 Ω
CKP sensor peak voltage 5.0 V and more (When cranking)
IAP sensor input voltage 4.5 – 5.5 V
IAP sensor output voltage Approx. 2.5 V at idle speed
TP sensor input voltage 4.5 – 5.5 V
TP sensor resistance
Closed
Approx. 1.12 kΩ
Opened
Approx. 4.26 kΩ
TP sensor output voltage
Closed
Approx. 1.12 V
Opened
Approx. 4.26 V
ECT sensor input voltage 4.5 – 5.5 V
ECT sensor resistance Approx. 2.45 kΩ at 20 °C (68 °F)
IAT sensor input voltage 4.5 – 5.5 V
IAT sensor resistance Approx 2.45 kΩ at 20 °C (68 °F)
AP sensor input voltage 4.5 – 5.5 V
AP sensor output voltage Approx. 4.0 V at 100 kPa (760 mmHg)
TO sensor resistance 19.1 – 19.7 kΩ
TO sensor voltage 1.4 V and less
GP switch voltage 0.6 V and more (From 1st to top)
Injector voltage Battery voltage
Ignition coil primary peak volt-
age
200 V and more (When cranking)
STP sensor input voltage 4.5 – 5.5 V
STP sensor resistance
Closed
Approx. 0.58 kΩ
Opened
Approx. 4.38 kΩ
STP sensor output voltage
Closed
Approx. 0.58 V at input voltage is 5.0 V
Opened
Approx. 4.38 V at input voltage is 5.0 V
STV actuator resistance 7 – 14 Ω
Heated oxygen sensor output
voltage
0.4 V and less at idle speed E-02, 19
0.6 V and more at 3 000 r/min E-02, 19
Heated oxygen sensor resis-
tance
4 – 5 Ω at 23 °C (73.4 °F) E-02, 19
PAIR solenoid valve resistance 20 – 24 Ω at 20 °C (68 °F)