1. Arrow symbols
Step between the various tool fields
by pressing the up or down arrow
symbols. You can always leave the tool
menu with the MENU button.
2. Clock
The clock must be set if automatic
nighttime mode or automatic start is to
be used. If 12V voltage is lost, the clock
will be reset and correct time will no
longer be displayed. This is prevented
with an optional AA battery backup.
3. Automatic night-time mode
This function is used when you want
to programme the central heating to
automatically lower the temperature
at night and raise the temperature in
the morning.
4. Starting the boiler automatically
This function is used to start the boiler
automatically at a later point of time.
With automatic start, the boiler works
for 24 hours and then stops. After that,
it repeats the automatic start once a
week; at the same day and time, as
long as the function is activated. For
automatic start to function, the On/Off
button must be set in the OFF position.
5. Constant pump operation
Cont.: With this function selected the
pump is permanently on. (NB., this
function limits the supply of hot water,
particularly when there is a low heating
requirement) Therm: With this function
selected the pump is controlled by the
panel/room sensor. This is the normal
operating mode for heating the vehicle
and obtaining a normal supply of hot
water. Factory setting is Therm.
A
6. *Pump Auto / 12V
In the Auto mode, the 230V pump
operates, and when 230V is
disconnected, the 12V pump starts. In
12V mode, the 12V pump is used even
if 230V is connected. The Auto function
is activated in the factory setting.
7. *Pump speed
The circulation pump’s capacity can be
remote controlled from the panel.
Note: A pump with remote control must be
installed in order that this function can be
used (see the manual for the vehicle, boat
or building).
8. *LPG bottle full/empty
This function is used in combination
with the cylinder changeover
(DuoComfort or DuoControl) and
indicates if the LPG bottle is full or
empty. This function can also be used
to control defroster heating of the
cylinder changeover using an EisEx
defroster.
Note: The cylinder changeover (DuoComfort
or DuoControl) must be installed in order for
this function to work (see the manual for the
vehicle, boat or building).
9. Automatic anti-bacterial
mode (legionella)
At 02.00 at night (if the clock is set)
the boiler starts and works according
to “Hot water boost” (see section 5).
This is in order to reduce the risk of
legionella. The function is deactivated
in the factory setting.