If you want to change the destination device, press F5Device Change, switch the cursor to the
desire device and pressEnter, then the below left column data structure will change, according
to the selected device .
Use】【to select file.
Move the cursor to the export file and press F2 SelectorSpaceto remark file.
After remarked all of the export file, press F1Copy then all of the remarked file will export from
controller to outer device.
Execute
Command
5 Buttons type: F2 ProgramF4 File ManagerF5 Execute
8 Buttons type: F2 ProgramF8 File ManagerF5 Execute
Function
Execute current program. and also change the screen to the monitor page.
Operation Method
Use】【to select file, and then pressExecutethe selected file will be the executive file.
Note
This function is invalid when machining.
Choose DNC File
Command
5 Buttons type: F2 ProgramF4 File ManagerNextF6 Execute
8 Buttons type: F2 ProgramF8 File ManagerF6 Execute
Function
Execute program stored in external devices, such as USB/Network.
Operation Method
Use】【to select file, and then pressConfirmthe selected file to be executed.
Title of selected file will be showed : DNC + file name
Note
Valid from -6MDs/6s2.2.0(10.116.10) 11s2.2.1(10.116.10A) 21s2.2.0(10.116.10) 20s
10.116.24
When a file reading fail, the control will retry 100 times before pop up a error message
A DNC program must use M30 as the end of program
USB DNC function does not support MACRO function
USB DNC function supports O888800, O999900, and Pr3851=0 functions (after 2.2.5)
When M98, G65, or G66 is used, the subprogram must be stored in controller
4.7 Offset/Setting (MainFenu: F3)
Path
5 key, 8 Key F3 Offset/Setting
10+8 key G3 Offset/Setting
Explanation
Offset/Setting function setup are under this fenubar group
Able to switch between pages in the group with hot keyOffset/Setting