36
8 - Technical Data
Heating
Indoor Unit PAW-200W5APAC
Outdoor Unit U-200PZH2E8
Item
Symbol Value Unit Item Symbol Value Unit
Rated heat output
Design load for heating
Prated
(Pdesign)
17 kW
Seasonal space heating energy
efficiency
η
s,h
178 %
Declared capacity for heating for part load at indoor
temperature 20°C and outdoor temperature Tj
Declared COP for part load at indoor
temperature 20°C and outdoor temperature Tj
Tj = -7
Pdh 15,22 kW
Tj = -7
COP 2,93 - or %
Tj = +2
Pdh 9,26 kW
Tj = +2
COP 4,17 - or %
Tj = +7
Pdh 5,95 kW
Tj = +7
COP 6,40 - or %
Tj = +12
Pdh 4,95 kW
Tj = +12
COP 8,59 - or %
Tj = bivalent temperature Pdh 17,20 kW Tj = bivalent temperature COP 2,10 - or %
Tj = operation limit
temperature
Pdh 13,43 kW
Tj = operation limit
temperature
COP 1,70 - or %
Tj = -15
(if TOL is < -20 )
Pdh - kW
Tj = -15
(if TOL is < -20 )
COP - - or %
Bivalent temperature Tbiv -10
Operation Limit temperature TOL -20
Degradation co-efficient Cdh 0,9 - -
Power consumption in modes other than active mode
-
Off mode POFF 0,028 kW
Thermostat off mode PTO 0,130 kW
Standby mode PSB 0,028 kW
Crankcase heater mode PCK 0,009 kW
Other Items Other Items
Sound power level (outdoor) LWA 49 / 79 dB Rated air flow rate, outdoors - 9.840 m
3
/h
Emission of Nox Nox - mg/kWh -
Annual (eletrical) energy
consumption
QHE 7.837 kWh
8.8 Performance Specifications