14
| Configuration
Icon Text
Description
Vacuum
cleaner
Function sets speed of supply air fan to High level and extract air fan to Low
level to increase air pressure within the apartment for better dust collection
through central vacuum cleaner.
Function can be activated via digital input Central Vacuum Cleaner
Function.
Always active while digital input is activated.
Cooker Hood
Sets speed of both supply and extract air fans to Maximum level to increase
airflow in the cooker hood.
Function can be activated via digital input Cooker Hood Function.
User lock
Function indicates that the system is locked with a password and cannot be
edited or settings changed in any way. System must be unlocked first to make
changes.
Configurable
Digital Input
1
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
High–priority function.
Configurable
Digital Input
2
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Mid–priority function.
Configurable
Digital Input
3
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Low–priority function.
Pressure
Guard
Configurable digital input for pressure guard connection. Airflow levels for both
fans are freely configurable.
5.7 Main menu
5.7.1 Unit Information
A basic read-only information about status of the unit, configured components and inputs/outputs.
5.7.1.1 Components
Type and settings of heat exchanger, heater, cooler, extra controller.
5.7.1.2 Sensors
Values from sensors and load of fans (rpm).
5.7.1.3 Input Status
Status of configured analog, digital and universal inputs. Connected component type and raw value (volts) is displayed.
5.7.1.4 Output Status
Status of configured analog, digital and universal outputs. Connected component type and value (volts) is displayed.
5.7.1.5 Unit Version
Unit model name, manufacturer number, serial number and unit software versions for Mainboard, HMI and IAM.
5.7.2 Alarms
A detailed information about active system alarms and alarm log of last 20 events.