JW weighing scales operation manual REV: C1, June 2012 JW weighing scales operation manual
Press ZERO to confirm when display gets stable.
Display will be show previous calibration weight and start to blink
first digit, if necessary enter the calibration weight value by
pressing MODE and % keys.
Press ZERO to confirm, display will be show “load”
Place the load on the platform.
Press ZERO to confirm when display gets stable.
Calibration will be finish and will start to self test to come normal
weighing.
Note: Calibration weight should be 1/3
rd
of the scale capacity.
Linear Calibration
Turn on the scale and press TARE key during the self test..
Display will be shown ”p Cal”.
Press TARE key to select “p1 Lcal”
Press ZERO to confirm, display will be show “unld”
Remove all weight from the platform.
Press ZERO to confirm when display gets stable.
Display will be show 1/3
rd
of the scale capacity
Place the calibration weight on the platform
Display will be show 2/3
rd
of the scale capacity
Place the calibration weight on the platform
Press ZERO to confirm when display gets stable.
Display will be show full of the scale capacity
Place the full capacity of the calibration weight on the platform.
Press ZERO to confirm when display gets stable.
Linear Calibration has finished and will start self test to come to normal
weighing.
-8--
1. INTRODUCTION
The JW series weighing scales are suitable for general weighing,
check weighing, parts counting, and percent weighing.
Capacities from 6kg to 45kg
25 membrane keys
Rechargeable battery provide up to 70 hours of continues use
(without backlight)
Large 52mm LCD with white LED back light display.
2. NAMES AND FUNCTIONS
2.1 Key Board