NB/NHB Series Technical Manual
- 16 -
Menu
Sub Menu
Description
F1 unt
N.A
F 2 bl
El au
To set back light automatic on
El on
To set back light always on
El off
To set back light always off
F3 com
S 23 2
S usb
Select first RS 232 or USB
P prt
By pressing Print key , weighing
value will be added to the
memory and print the print out
P cont
Send data continuous
P auto
Automatic accumulation.
Individual weighing values are
automatically added
P ask
ASK mode
Command R: read data
Command T: Tare
Command Z: Zero
Wirele
Wireless (optional)
Set BAUD rate
After setting the RS 232 mode, display will be shown current
baud rate b XXX.
Baud rate Options: b600, b1200, b2400, b4800 and
b9600
Set Printer type
After setting BAUD rate display will be show the printer
type(only for
P PRT
and
P auto
option)
Lp 50
Label Printer
Tp
Ticket Printer
Set Printer type
After setting BAUD rate display will be show the printer type
Lp 50
Label Printer
Tp
Ticket Printer
Sale m
Sale N
Accumulation function
enable;units change enable
Sale Y
Accumulation function
disable;units change disable
tech
pin
Enter the password
P 1 lin
Linear Calibration
P 2 Cal
Normal Calibration