44 Base Station Specifications TB9300 Specifications Manual
© Tait International Limited August 2022
1.9.4 Heat Load Values
These measurements were carried out with the base station transmitting at
its rated output power with all front panel fans running. All measurements
were carried out with no load on the auxiliary power supply.
1.9.5 Dimensions and Weight
1.9.6 Reliability
WBtu/h
B Band
Single 50 W base station
Dual 50 W base station
100 W base station
121 W
219 W
231 W
413 Btu/h
747 Btu/h
788 Btu/h
G & H Band
Single 50 W base station
Dual 50 W base station
100 W base station
137 W
244 W
245 W
467 Btu/h
833 Btu/h
836 Btu/h
K Band
Single 50 W base station
Dual 50 W base station
100 W base station
151 W
245 W
257 W
516 Btu/h
837 Btu/h
878 Btu/h
L2 Band
100 W base station 257 W 878 Btu/h
Dimensions
Height
Width
Length
Subrack only
Including front panel
176.8 mm (7 in)
482.6 mm (19 in)
385 mm (15.2 in)
400.5 mm (15.8 in)
Weight
a
Single 50 W base station
Dual 50 W base station
100 W base station
21.5 kg (47.4 lb)
28.6 kg (63.1 lb)
22.8 kg (50.3 lb)
a. With AC and DC PMU.
MTBF 140,000 hours minimum (based on field returns)