T2200P Weighing Indicator User’s Guide
- 14 -
SECTION 9 CALIBRATION
The scale can be calibrated using the following procedure. For a more detailed
method of calibrating the scale it will be necessary to enter the secure Programming
Menu. See detail in section 12.
The T2200P weighing indicator can calibrate using either metric or pound weights,
depending on the weighing unit in use before calibration. The display will show
either "kg" or "lb" to identify the weights expected.
PROCEDURE
Turn the power off.
Turn the power back on, during the counting from 9 to 0 press the FUNC key.
The display will show "CAL " for a few seconds. While it is showing "CAL "
press the SMPL, PRINT and TARE keys in sequence to enter the Calibration
section. The display will show "unLoAd".
Remove any weight from the platform. After stable indicator on, press the ZERO
key.
The display will show last calibrate weight value, you can use SMPL, SHIFT, TARE
key input new calibrate weight value (use SMPL, SHIFT key to move active digit, use
TARE key to change value), after you setting, press ZERO key to sure, display will
show "LoAd". Place the calibration weight on the scale. Press the ZERO key.
If the calibration is acceptable the display will show "PASS" and then return to normal.
If an error message is shown try calibration again as a disturbance may have
prevented a successful calibration.
If the problem persist then contact your dealer.
After calibration the scale should be checked to verify the calibration and linearity is
correct. If necessary repeat calibration, especially be certain the scale is stable
before accepting any weight.