72
-
Incorrect charging characteristics or the use of inappro-
priate chargers may result in early failure or the quick
destruction of batteries.
-
-
- Standard value: At least approx. 20% of the available
capacity should be used up before recharging the bat-
tery.
-
-
- Before recommissioning, the batteries should under-
go another complete charging cycle.
-
-
The user may be injured by electric shock.
25.6 V
Battery
plug
Power Board
Drive direction
Forward
Charger
internal
Mains
red
black
Charger
external
25.6 V
25.6 V
Battery
plug
Power Board
Drive direction
Forward
red
black
Charger
external
Mains
• Connect the external battery charger with the battery
charging plug of the machine.