66
Malfunctions
Technical data
Accessories
Malfunction Possible causes Troubleshooting Page
Machine without function
Machine is switched off
• Switch on the main switch
61
No power supply
• Insert the plug into the mains sock-
et
Main cord defect • Replace the main cord
Motor does not turn • Contact your service partner
Foot pedal is locked Unlock the foot pedal 63
Defective safety switch • Contact your service partner
Pad does not turn
Motor runs, but tool does not rotate
• Drive belt torn or loose
• Contact your service partner
Defective electronic component • Contact your service partner
Machine has no function, indicator
light is on
Machine overload, overload switch
was activated
• Wait a few minutes and try again
(overload switch resets automati-
cally)
Machine does not reach nominal
speed, overcurrent is activated
Machine overload • Check the work technique
Undervoltage: Main cord is too long
• Remove power supply cord exten-
sion
• Check the voltage rating
Machine does not run smoothly Pad deformed or damaged • Replace pad62
Machine ergodisc 2000
Working width 50 cm
Dimensions (LxWxH) 108 x 59 x 119 cm
Maximum weight of operational machine 54 kg
Rated voltage 220-240V~ 100-120V~ 220V~ AC
Frequency 50 60 60 Hz
Rated power, nominal 1500 W
Values according to IEC 60335-2-67
Sound pressure level LpA 68 dB(A)
Uncertainty KpA 2.5 dB(A)
Vibration <2.5 m/s2
Uncertainty K 0.25 m/s2
Splash water guard IPX0
Protection class I
No. Item
7521297 One-way fleece dust bag
Various pads (pink, red or special pads)