EasyManua.ls Logo

tau K206MA - User Manual

tau K206MA
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GUIDA ALL’INSTALLAZIONE
INSTALLATION GUIDE
INSTALLATIONSANLEITUNG
NOTICE D’INSTALLATION
GUÍA PARA LA INSTALACIÓN
GUIA DE INSTALAÇÃO
IT - Istruzioni originali
K206MA
K206MA
D-MNL0K206MA 20-01-2023- Rev.28
Ver. Firmware 9.01
Question and Answer IconNeed help?

Do you have a question about the tau K206MA and is the answer not in the manual?

Summary

Safety Warnings

General Safety Precautions

Essential safety measures and precautions for installation and use.

Manufacturer Liability Disclaimer

Statement on manufacturer's responsibility for improper use or installation.

Installation Guidelines

Mechanical Checks and Earthing

Procedures for verifying mechanical setup and system earthing.

Cable Handling Recommendations

Guidelines for proper cable selection and usage to prevent issues.

2. Introduction

3. Technical Characteristics

4. Terminal Connections

Photocell and Sensitive Edge Inputs

Details for connecting photocells (7-9) and sensitive edge (7-10).

Auxiliary Outputs and Inputs

Information on AUX, TX Photocell, and Flashing Light connections.

Electromagnet and Bar LED

Connections for electromagnet (16-17) and bar LED (16-18).

Radio, Aerial, Motor, and Encoder

Wiring for radio, aerial, motor, and encoder connections (19-32).

5. Logic Adjustments

Trimmer Adjustments

Explanation of T.R.A., T.C.A., and F.R. trimmer functions and adjustments.

Dip Switch Settings

Guide to configuring the control unit using dip switches 1 through 8.

Barrier Model and Bar Length Selection

Dip Switch Settings for Barrier Model

Table detailing dip switch configurations for barrier models and lengths.

Sensitive Edge Configuration

Setting for resistive or fixed sensitive edge using dip switch 12.

6. Memorization Procedure

Pre-Memorization Checks

Ensuring mechanical balance and limit switches are correctly set.

Learning Process Steps

Step-by-step guide to programming the automation limits and parameters.

Stopping and Restarting Memorization

How to stop or restart the memorization process, including error handling.

7. K206 MA Characteristics

Timer-Operated Cycles

Configuration of automatic opening/closing cycles using a timer.

Battery Charger Board

Functionality of the integrated battery charger and voltage monitoring.

Obstacle Detection

Setting and function of obstacle detection via FR trimmer.

8. Diagnostics LEDs

DL1-DL6 Input Status LEDs

Interpretation of LEDs indicating status of input buttons and safety devices.

DL7 Battery Status LED

LED codes for battery charge status and system voltage.

DL8 Logic and Function Status LED

LED codes for board logic errors and operational status.

LED Error Codes

DL8 Error Codes

Detailed interpretation of DL8 LED flashes for various error conditions.

DL7 and DL8 Simultaneous Errors

Codes indicating factory reset or radio channel cancellation.

9. Absorption Check Function

Function Overview

Monitoring motor absorption to assess motor stress during operation.

Activation and Visualization

How to activate the function and interpret the DL7/DL8 LED indicators.

10. Restoring Automatic Operation

Manual Operation and Power Failure

Procedures after manual operation or mains power failure for realignment.

11. 433.92 MHz Built-in Radio Receiver

Learning System for Radio Controls

Step-by-step guide for associating radio control devices with the receiver.

Remote Programming

Procedure for remote self-learning of new transmitters.

Cancelling Radio Control Codes

Instructions for deleting programmed radio control devices.

Memory Capacity Expansion

Information on upgrading the code memory capacity with expansion cards.

Radio Memory Reset

Procedure for resetting the radio receiver memory.

Hard Reset (Factory Setting)

Procedure for performing a factory reset of the control unit.

12. Malfunctions: Possible Causes and Solution

Automation Does Not Start

Troubleshooting steps for when the automation fails to initiate.

Radio Control Range Issues

Causes and solutions for limited range of radio control operation.

Incorrect Gate Operation Direction

Procedure to correct the gate opening or closing in the wrong direction.

13. Guarantee: General Conditions

Warranty Period and Coverage

Details of the product guarantee period and what it covers.

Exclusions from Guarantee

Cases and conditions not covered by the product warranty.

Manufacturers Declaration of Incorporation

Summary

Safety Warnings

General Safety Precautions

Essential safety measures and precautions for installation and use.

Manufacturer Liability Disclaimer

Statement on manufacturer's responsibility for improper use or installation.

Installation Guidelines

Mechanical Checks and Earthing

Procedures for verifying mechanical setup and system earthing.

Cable Handling Recommendations

Guidelines for proper cable selection and usage to prevent issues.

2. Introduction

3. Technical Characteristics

4. Terminal Connections

Photocell and Sensitive Edge Inputs

Details for connecting photocells (7-9) and sensitive edge (7-10).

Auxiliary Outputs and Inputs

Information on AUX, TX Photocell, and Flashing Light connections.

Electromagnet and Bar LED

Connections for electromagnet (16-17) and bar LED (16-18).

Radio, Aerial, Motor, and Encoder

Wiring for radio, aerial, motor, and encoder connections (19-32).

5. Logic Adjustments

Trimmer Adjustments

Explanation of T.R.A., T.C.A., and F.R. trimmer functions and adjustments.

Dip Switch Settings

Guide to configuring the control unit using dip switches 1 through 8.

Barrier Model and Bar Length Selection

Dip Switch Settings for Barrier Model

Table detailing dip switch configurations for barrier models and lengths.

Sensitive Edge Configuration

Setting for resistive or fixed sensitive edge using dip switch 12.

6. Memorization Procedure

Pre-Memorization Checks

Ensuring mechanical balance and limit switches are correctly set.

Learning Process Steps

Step-by-step guide to programming the automation limits and parameters.

Stopping and Restarting Memorization

How to stop or restart the memorization process, including error handling.

7. K206 MA Characteristics

Timer-Operated Cycles

Configuration of automatic opening/closing cycles using a timer.

Battery Charger Board

Functionality of the integrated battery charger and voltage monitoring.

Obstacle Detection

Setting and function of obstacle detection via FR trimmer.

8. Diagnostics LEDs

DL1-DL6 Input Status LEDs

Interpretation of LEDs indicating status of input buttons and safety devices.

DL7 Battery Status LED

LED codes for battery charge status and system voltage.

DL8 Logic and Function Status LED

LED codes for board logic errors and operational status.

LED Error Codes

DL8 Error Codes

Detailed interpretation of DL8 LED flashes for various error conditions.

DL7 and DL8 Simultaneous Errors

Codes indicating factory reset or radio channel cancellation.

9. Absorption Check Function

Function Overview

Monitoring motor absorption to assess motor stress during operation.

Activation and Visualization

How to activate the function and interpret the DL7/DL8 LED indicators.

10. Restoring Automatic Operation

Manual Operation and Power Failure

Procedures after manual operation or mains power failure for realignment.

11. 433.92 MHz Built-in Radio Receiver

Learning System for Radio Controls

Step-by-step guide for associating radio control devices with the receiver.

Remote Programming

Procedure for remote self-learning of new transmitters.

Cancelling Radio Control Codes

Instructions for deleting programmed radio control devices.

Memory Capacity Expansion

Information on upgrading the code memory capacity with expansion cards.

Radio Memory Reset

Procedure for resetting the radio receiver memory.

Hard Reset (Factory Setting)

Procedure for performing a factory reset of the control unit.

12. Malfunctions: Possible Causes and Solution

Automation Does Not Start

Troubleshooting steps for when the automation fails to initiate.

Radio Control Range Issues

Causes and solutions for limited range of radio control operation.

Incorrect Gate Operation Direction

Procedure to correct the gate opening or closing in the wrong direction.

13. Guarantee: General Conditions

Warranty Period and Coverage

Details of the product guarantee period and what it covers.

Exclusions from Guarantee

Cases and conditions not covered by the product warranty.

Manufacturers Declaration of Incorporation

tau K206MA Specifications

General IconGeneral
Brandtau
ModelK206MA
CategoryControl Panel
LanguageEnglish

Related product manuals