SAFETY
3-3
Model 0736
Safety
3
ATTENTION: Connect to a circuit protected by fuses or
HACR type circuit breaker.
ATTENTION: Only copper conductors (Cu). Minimum
section 10AWG (4mm
2
1N 230V; 4mm
2
3 230V; 2.5mm
2
3N 400V)
ATTENTION: This equipment must be properly
grounded! Failure to do so can result in severe personal
injury from electrical shock!
ATTENTION: Disconnect the power supply before
servicing the machine.
For decommissioning, comply with the standards in force
in the country where it is used.
This machine is RoHS
2
compliant.
Battery type CR2032 inside. For decommissioning,
comply with the standards in force in the country where it
is used.
Water pressure limits (for water-cooled models only).
Use only R404A refrigerant that conforms to the AHRI
Standard 700 specification.
Electrical Box Warning Label
DANGER: High voltage inside, danger of electrocution.
Disconnect the Power Supply Before Servicing the Unit.
ATTENTION: Only copper conductors (Cu). Minimum
section 10AWG (4mm
2
1N 230V; 4mm
2
3 230V; 2.5mm
2
3N 400V).
ATTENTION: Connect to a circuit protected by fuses or
HACR type circuit breaker.
To correct rotation on a three-phase machine,
interchange any two incoming power lines at the machine
main terminal block only.
To correct rotation on a single-phase machine, change
the leads inside the beater motor. (Follow diagram
printed on motor.)