19
Models 340, 341, 342 Operating Procedures
110713
Figure 28
Step 4
Place the hopper cover into position.
Figure 29
Step 5
(Optional Flavor Rack Assembly)
To make a refreshing slush product, add the desired
flavor to the bottom of the cup by pressing the pump
handle of the flavor bottle. Move the draw handle to the
right and fill the cup, mixing the flavor with the product
being drawn.
Figure 30
Remote Auto Fill System
Your Taylor freezer has been factory equipped with a
Remote Auto Fill System. When the MIX LOW light
illuminates, press the FILL button located under the
control channel. The mix supply to the hopper will be
replenished automatically from remote mix tanks. The
MIX LOW light will extinguish when the mix supply is
replenished. The fill time takes approximately 5
minutes and then the system automatically shuts off.
Note: Leave the hopper cover on while filling, as some
splashing may occur.
IMPORTANT: As a safety feature, the Auto Fill System
cannot be activated unless the MIX LOW light is
illuminated.
Specifications:
Remote Auto Fill System Components:
5 gallon mix tank(s), air compressor assembly,
solenoid valve, 5 minute timer, and fill switch.
Recommended pressure (air compressor):
12--15 PSI (83--103 kPa)
IMPORTANT: Do not exceed 15 PSI or over--filling
may occur.
Closing Procedure