12
Introduction
Models C706 & C707
Symbol Definitions
To better communicate in the International arena,
symbols have replaced words on many of our operator
switches, function, and fault indicators. Your Taylor
equipment is designed with these International
symbols.
The following chart identifies the symbol definitions.
=OFF
=ON
=MIXLOW
= MIX OUT
=MIXREF
= STANDBY
= WASH
=AUTO
=PUMP
Power Switch
When placed in the ON position, the power switch
allows SOFTECH control panel operation.
Indicator Lights
MIX LOW
When the MIX LOW light begins to flash, it indicates
that the mix tank has a low supply of mix and should
be refilled as soon as possible.
MIX OUT
When the MIX OUT light begins to flash, it indicates
that the mix tank has been almost completely
exhausted and has an insufficient supply of mix to
operate the freezer. At this time, the STANDBY and
AUTO modes are locked out and the freezer shuts
down. To initiate the refrigeration system, add mix to
the tank and press the AUTO key. The freezer will
automatically begin operation.
MIX REF Key
When the MIX REF key is pressed, the light comes on
indicating the mix hopper refrigeration system is
operating. The MIX REF function cannot be cancelled
unless the AUTO or STANDBY modes are cancelled
first.
STANDBY Key
The Separate Hopper Refrigeration System (SHR)
and the Cylinder Temperature Retention System
(CTR) are standard features. The SHR incorporates
the use of a separate small refrigeration system to
maintain the mix in the hopper below 40_(4.4_C) to
assure bacteria control. The CTR works with the SHR
to maintain a good quality product. During long No
Sale” periods, it is necessary to warm the product in
the freezing cylinder to approximately 35_Fto40_F
(1.7_Cto4.4_C) to prevent overbeating and product
breakdown.
To activate the SHR and CTR, press the STANDBY
key. On the model C707, remove the air orifice and
place the air tube (end without the hole) into the mix
inlet hole.
When the STANDBY key is pressed, the light comes
on, indicating the CTR (Cylinder Temperature
Retention System) has been activated. In the
STANDBY mode, the WASH and AUTO functions are
automatically cancelled. The MIX REF function is
automatically locked in to maintain the mix in the
hopper.
To resume normal operation, press the AUTO key.
When the unit cycles off, the product in the freezing
cylinder will be at serving viscosity. On the model
C707, place the air tube (end with the hole) into the
mix inlet hole and install the air orifice.
WASH Key
When the WASH key is pressed, the light comes on.
This indicates beater motor operation. The STANDBY
or AUTO modes must be cancelled first to activate the
W ASH mode.