Introduction
Models C706 & C707
Safety
_________________________________
We at Taylor Company, are committed to
manufacturing safe operating and serviceable
equipment. The many built-in safety features that are
part of all Taylor equipment are aimed at protecting
operators and trained service technicians alike.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.
This manual is intended exclusively for Taylor
Company authorized service personnel.
Refrigerant
_________________________________
Taylor Company uses R404A refrigerant in the
standard softserve freezers. This refrigerant is
generally considered non-toxic and non-flammable;
however , any gas under pressure is potentially
hazardous.
NEVER fill any refrigerant cylinder completely
with liquid. Filling the cylinder to approximately 80%
will allow for normal expansion.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
The Taylor Company reminds technicians
to be cautious of government laws regarding
refrigerant recovery, recycling, and reclaiming
systems. If you have any questions regarding
these laws, please contact the factory Service
Department.
Compressor Warranty Disclaimer
_________________________________
The refrigeration compressor(s) on this machine are
warranted for the term indicated on the warranty card
accompanying this machine. However, due to the
Montreal Protocol and the U.S. Clean Air Act
Amendments of 1990, many new refrigerants are
being tested and developed; thus seeking their way
into the service industry. Some of these new
refrigerants are being advertised as drop-in
replacements for numerous applications. It should be
noted that, in the event of ordinary service to this
machine’s refrigeration system, only t he refrigerant
specified on the affixed data label should be used. The
unauthorized use of alternate refrigerants will void
your compressor warranty. It will be the owners’
responsibility to make this fact known to any
technicians they employ.
It should be noted, that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service
to this machine, Taylor has no obligation to either
supply or provide its replacement either at billable or
unbillable terms.
The Taylor Company will continue to monitor the
industry and test new alternates as they are being
developed. Should a new alternate prove, through our
testing, that it would be accepted as a drop-in
replacement, then the above disclaimer would
become null and void. To find out the current status of
an alternate refrigerant as it relates to your
compressor, call the local Taylor Distributor or the
Taylor Factory. Be prepared to provide the
model/serial number of the unit in question.

Other manuals for Taylor C706

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C706 and is the answer not in the manual?

Taylor C706 Specifications

General IconGeneral
ModelC706
CategoryFreezer
Refrigeration SystemAir Cooled
Air CooledYes
Water CooledNo
Weight220 lbs

Related product manuals